Markets
Global markets
Supplying to 60+ countries and regions. The regions below are groupings of countries, not single-country pages: a regional hub is built only where there is real commercial value and distinct local knowledge to share.
Regional hub
Asia
- Cable has been supplied to 15 markets in this region — company export record, 2011–2023.
- IEC 60502 is the usual reference for power cables in tender documents. Designs to BS, DIN and ICEA are supplied when the specification calls for them.
- High water tables and monsoon conditions make armour and moisture barriers a routine requirement on directly buried cable routes.
Middle East
- Cable has been supplied to 8 markets in this region — company export record, 2011–2023.
- High ambient temperature and solar exposure drive conductor sizing: current ratings are calculated to IEC 60287 against the actual installation conditions of each project.
- Sandy soil with high thermal resistivity is common on buried routes, and armour plus moisture barriers are frequently specified.
Central Asia
- Cable has been supplied to 5 markets in this region — company export record, 2011–2023.
- Legacy installations frequently follow GOST-based designs. Send the original specification or the GOST type designation and we will map it to the nearest IEC design and confirm the differences with you — no substitution is made without verification.
- Low winter temperatures affect sheath flexibility and handling on site; compounds are selected to suit the minimum on-site temperature.
Africa
- Cable has been supplied to 16 markets in this region — company export record, 2011–2023.
- IEC designs are the common reference; some national utilities still specify BS-derived constructions, so the applicable standard is confirmed before the quotation is prepared.
- Projects are frequently funded by development institutions or delivered by EPC contractors, and inspection and documentation requirements are set by the funding party.
Europe
- Cable has been supplied to 7 markets in this region — company export record, 2011–2023.
- European specifications normally cite EN/IEC harmonised standards. Halogen-free, low-smoke constructions are commonly required for public buildings, transport and other enclosed spaces.
- Cables installed in buildings in the EU are subject to the Construction Products Regulation; confirm the required reaction-to-fire class before you send your enquiry.
Other Markets
- Cable has been supplied to 5 markets across the Americas and Oceania — company export record, 2011–2023.
- Australia and New Zealand commonly specify AS/NZS designs, while the Americas commonly reference ICEA, UL or NEC-derived constructions. The applicable standard is confirmed against the project documents.
- For long ocean shipments, drum packing, end sealing and sequential length marking are standard specification requirements.